此页面服务由第三方为您提供
所在位置:首页 > 服务项目 > 详情

YASKAWA安川变频器不显示故维修郑州地区维修

发布时间:2023-09-06 06:36:05 人气:226

易成电气专业维修安川变频器F7系列

CIMR-F7B40P4 CIMR-F7B40P7 CIMR-F7B41P5 CIMR-F7B42P2 CIMR-F7B43P7 CIMR-F7B45P5 CIMR-F7B47P5 CIMR-F7B4011 CIMR-F7B4015 CIMR-F7B4018 CIMR-F7B4022 CIMR-F7B4030 CIMR-F7B4037 CIMR-F7B4045 CIMR-F7B4055 CIMR-F7B4075 CIMR-F7B4090 CIMR-F7B4110 CIMR-F7B4132 CIMR-F7B4160 CIMR-F7B4185 CIMR-F7B4220 CIMR-F7B4300 CIMR-F7A20P4 CIMR-F7A20P7 CIMR-F7A21P5 CIMR-F7A22P2 CIMR-F7A23P7 CIMR-F7A25P5 CIMR-F7A27P5 CIMR-F7A2011 CIMR-F7A2015 CIMR-F7A2018 CIMR-F7A2022 CIMR-F7A2030 CIMR-F7A2037 CIMR-F7A2045 CIMR-F7A2055 CIMR-F7A2075 CIMR-F7A2090 CIMR-F7A2110

安川变频器J7系列u=2989743139,2386608108&fm=26&gp=0.jpg

CIMR-J7AA40P20 CIMR-J7AA40P40

CIMR-J7AA40P70 CIMR-J7AA41P50

CIMR-J7AA42P20 CIMR-J7AA43P70

VS-606V7系列单相200V级

CIMR-V7ATB0P1 CIMR-V7ATB0P2 CIMR-V7ATB0P4 CIMR-V7ATB0P7 CIMR-V7ATB1P5

CIMR-V7ATB2P2

CIMR-V7ATB3P7 CIMR-J7AA40P2 CIMR-J7AA40P4 CIMR-J7AA40P7 CIMR-J7AA41P5

CIMR-J7AA42P2

CIMR-J7AA43P0 CIMR-J7AA43P7

安川变频器无法启动维修、故障现象:操作控制面板PMU显示屏显示“F008”报警,变频器上电自检,显示“009”开机准备状态,但是随后显示“F008”不能启动。

  检查处理(参见图7):检查底板电压、电流检测部分,发现R56在线测量阻值为4.3kΩ,正常值为900Ω,用热风枪拆下测量阻值为1MΩ,已经烧坏。更换新电阻值后,运行正常。u=205868445,3596716957&fm=26&gp=0.jpg

2.5 西门子6SE70系列变频器的操作控制面板PMU液晶显示屏上显示“F011”报警

(1)故障现象:操作控制面板PMU液晶显示屏显示“F011”报警,不能复位

  检查处理(参见图7):电压检测块N1(TL084)7脚外接47Ω电阻变为15Ω,V2(IRF520)G极保护电阻由正常阻值10Ω变为340kΩ,更换后,运行正常。

(2)故障现象:操作控制面板PMU液晶显示屏显示“F011”报警,且变频器有焦糊味。

  检查处理(参见图1、图5、图10):测量N2第20脚输出电压只有5.1V,1脚输出电压为16.5V,检查发现N2第9脚接1kΩ电阻烧坏,N5第1脚接100kΩ电阻变为20MΩ,3脚外接10Ω电阻变为2MΩ,触发板A22第3脚与第4脚接4.7kΩ电阻烧坏,更换上述电阻后,运行正常。

u=1294409736,3634370549&fm=26&gp=0.jpg

NCU盒7段数码管没有显示,屏幕报警提示NC\PLC未连接,(ncu和PCU都有问题)

840D系统,现报2120号警(NCK风扇报警),更换了一块NCU盒后仍然出现2120报警--ncu坏了